LEGEND MAX™ Human IFN-β ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Interferon beta 1
Ave. Rating
Submit a Review
Product Citations
publications
Legend-MAX_Human-IFN-B-Elisa-Kit_021324
  • Legend-MAX_Human-IFN-B-Elisa-Kit_021324
Cat # Size Price Quantity Check Availability Save
449507 1 Pre-coated Plate 524€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

IFN-β is a type I class of interferon produced by macrophages, dendritic cells, endothelial cells and primarily fibroblasts. It plays a significant antiviral activity role within the innate immune response to infection, cell differentiation and anti-tumor defenses. Once secreted, it binds to a homologous receptor complex and activates the Jak/STAT pathway, resulting in upregulating genes that inhibit viral infection and regulate MHC class 1 antigens. Multiple sclerosis is characterized by a deficiency of IFN beta 1 and is commonly been used as an injectable treatment.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Human IFN-β Pre-Coated Plate
  • Human IFN-β Detection Antibody
  • Human IFN-β Standard
  • Assay Buffer B
  • Streptavidin-Polymer HRP
  • Wash Buffer (20X)
  • Substrate Solution D
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
0.91 ± 0.16 pg/mL
Standard Range
2.34 - 150 pg/mL
Materials Not Included
  • Microwell plates: BioLegend Cat. No. 423501 is recommended 
  • Wash Buffer: BioLegend Cat. No. 421601 is recommended, or PBS + 0.05% Tween-20 
  • Stop Solution: BioLegend Cat. No. 423001 is recommended, or acid solution, e.g. 2N H2SO4 
  • Plate Sealers: BioLegend Cat. No. 423601 is recommended 
  • PBS (Phosphate-Buffered Saline): 8.0 g NaCl, 1.16 g Na2HPO4 , 0.2 g KH2PO4 , 0.2 g KCl, add deionized water to 1 L; pH to 7.4, 0.2 μm filtered 
  • Deionized (DI) water 
  • A microplate reader capable of measuring absorbance at 450 nm 
  • Adjustable pipettes to measure volumes ranging from 2 μL to 1 mL 
  • Wash bottle or automated microplate washer 
  • Log-Log graph paper or software for data analysis 
  • Tubes to prepare standard dilutions
  • Timer

Antigen Details

Cell Type
B cells, Dendritic cells, Endothelial cells, Fibroblasts, Macrophages
Biology Area
Apoptosis/Tumor Suppressors/Cell Death, Cell Proliferation and Viability, COVID-19, Innate Immunity, Signal Transduction
Molecular Family
Cytokines/Chemokines, Innate Immune Signaling
Gene ID
3456 View all products for this Gene ID
UniProt
View information about IFN-beta on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 02.13.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account