LEGEND MAX™ Human Adiponectin (Acrp30) ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Adiponectin, Adipocyte complement-related protein of 30 kD (Acrp30), Adipose most abundant gene transcript 1 (apM1), Gelatin-binding protein of 28 kD (GBP28), ADIPOQ
Ave. Rating
Submit a Review
Product Citations
publications
Adiponectin_Human_ELISA_Kit_LegMax_022814
  • Adiponectin_Human_ELISA_Kit_LegMax_022814
Cat # Size Price Quantity Check Availability Save
442307 1 Pre-coated Plate 398€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Adiponectin is also referred to as Acrp30, AdipoQ, apM1, and gelatin binding protein of 28 kD (GBP-28), which in humans is encoded by the ADIPOQ gene. Adiponectin contains 244 amino acids with a collagen-like domain at the N-terminal and a globular domain at the C-terminal. The globular domain can be proteolytically truncated forming the globular adiponectin (gAdiponectin). This globular domain resembles the structure of the complement C1q and the TNF-a superfamily. Adiponectin exists in a wide range of homo-oligomers: a low-molecular weight (LMW) trimer, a medium molecular weight (MMW) hexamer, and a high molecular weight (HMW) multimer with little or no interconversion between the forms. Females generally have higher HMW than males in both proportion and absolute amounts. Adiponectin has two receptors (adipoRs)-1 and -2. AdipoR1 mRNA is detectable in skeletal muscle, spleen, lung, heart, kidney, and liver. AdipoR2 is expressed in liver, but also detectable in heart, lung, skeletal muscle, and kidney.

Adiponectin plays an important role in carbohydrate and lipid metabolism. It promotes insulin-sensitivity and protects cells from inflammation and apoptosis. It is also hypothesized to have anti-atherogenic activity. Normal circulating adiponectin level ranges from 4-30 µg/mL. Adiponectin levels are inversely correlated with body mass index (BMI). Low serum level of adiponectin is found in obesity, type 2 diabetes and those with coronary artery disease. Therefore, adiponectin serves as an important clinical biomarker for metabolic syndromes.

The LEGEND MAX™ Human Adiponectin (Acrp30) ELISA Kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a mouse monoclonal anti-human adiponectin antibody. The detection antibody is a biotinylated mouse monoclonal anti-human adiponectin antibody. This kit is specifically designed for the accurate quantitation of human adiponectin (including globular, LMW, MWM, and HMW adiponectin) from cell culture supernatant, serum, plasma, and other biological fluids. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Human Adiponectin Pre-coated 96 well Strip Microplate
  • Human Adiponectin Detection Antibody
  • Human Adiponectin Standard
  • Avidin-HRP B
  • Assay Buffer B
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
0.086 ng/mL
Standard Range
0.78 - 50 ng/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 μL to 1,000 μL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Polypropylene vials

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 02/28/2014

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account