Brilliant Violet 711™ anti-mouse CD117 (c-Kit) Antibody

Pricing & Availability
Clone
2B8 (See other available formats)
Regulatory Status
RUO
Other Names
c-KIT, Stem Cell Factor Receptor (SCFR)
Isotype
Rat IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
2B8_BV711_CD117_1_FC_063015.jpg
C57BL/6 mouse bone marrow cells were stained with CD11b FITC and CD117 (clone 2B8) Brilliant Violet 711™ (top) or Rat IgG2b, κ BV711™ Isotype Ctrl (bottom).
  • 2B8_BV711_CD117_1_FC_063015.jpg
    C57BL/6 mouse bone marrow cells were stained with CD11b FITC and CD117 (clone 2B8) Brilliant Violet 711™ (top) or Rat IgG2b, κ BV711™ Isotype Ctrl (bottom).
  • 2B8_BV711_CD117_2_FC_063015.jpg
Compare all formats See Brilliant Violet 711™ spectral data
Cat # Size Price Quantity Check Availability Save
105835 50 µg 273 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD117 is a 145 kD immunoglobulin superfamily member also known as c-Kit and stem cell factor receptor (SCFR). It is a transmembrane tyrosine-kinase receptor that binds the c-Kit ligand (also known as steel factor, stem cell factor, and mast cell growth factor). CD117 is expressed on hematopoietic stem cells (including multipotent hematopoietic stem cells, progenitors committed to myeloid and/or erythroid lineages, and T and B cell precursors), mast cells, and acute myeloid leukemia (AML) cells. CD117 interaction with its ligand is critical for the development of hematopoietic stem cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse bone marrow mast cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 711™ under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.25 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Brilliant Violet 711™ excites at 405 nm and emits at 711 nm. The bandpass filter 710/50 nm is recommended for detection, although filter optimization may be required depending on other fluorophores used. Be sure to verify that your cytometer configuration and software setup are appropriate for detecting this channel. Refer to your instrument manual or manufacturer for support. Brilliant Violet 711™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunoprecipitation1, immunohistochemistry of acetone fixed frozen sections2, and spatial biology (IBEX)5,6. The 2B8 antibody does not block c-Kit activity.

Application References

(PubMed link indicates BioLegend citation)
  1. Ikuta K, et al. 1992. P. Natl. Acad. Sci. USA 89:1502. (FC)
  2. Podd BS, et al. 2006. J. Immunol. 176:6532. PubMed (IHC)
  3. Bachelet I, et al. 2008. J. Immunol. 180:6064. PubMed (FC)
  4. Charles N, et al. 2010. Nat. Med. 16:701. PubMed (FC)
  5. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  6. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
Product Citations
  1. Schönberger K, et al. 2022. Cell Stem Cell. 29:131. PubMed
  2. Fistonich C, et al. 2018. J Exp Med. 215:2586. PubMed
  3. Zheng Z, et al. 2020. Cell Reports. 31(13):107819. PubMed
  4. Heil J, et al. 2021. Nat Commun. 12:6963. PubMed
  5. Rai S, et al. 2022. Nat Commun. 13:5346. PubMed
  6. Severe N et al. 2019. Cell Stem Cell. 25(4):570-583 . PubMed
RRID
AB_2565956 (BioLegend Cat. No. 105835)

Antigen Details

Structure
Ig superfamily, 145 kD
Distribution

Hematopoietic stem cells, AML, mast cells

Function
Growth factor receptor, tyrosine kinase
Ligand/Receptor
Stem Cell Factor (SCF)
Cell Type
Embryonic Stem Cells, Hematopoietic stem and progenitors, Leukemia, Mast cells, Mesenchymal Stem Cells
Biology Area
Immunology, Stem Cells
Molecular Family
CD Molecules
Antigen References

1. Barclay A, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Galli SJ, et al. 1994. Adv. Immunol. 55:1.
3. Ikuta K, et al. 1992. Annu. Rev. Immunol. 10:759.
4. Besmer P, et al. 1986. Nature 320:415.
5. Witte ON. 1990. Cell 63:5.

Gene ID
16590 View all products for this Gene ID
UniProt
View information about CD117 on UniProt.org

Other Formats

View All CD117 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-mouse CD117 (c-Kit) 2B8 FC
Biotin anti-mouse CD117 (c-Kit) 2B8 FC
FITC anti-mouse CD117 (c-Kit) 2B8 FC
PE anti-mouse CD117 (c-Kit) 2B8 FC
PE/Cyanine5 anti-mouse CD117 (c-Kit) 2B8 FC
Purified anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
PE/Cyanine7 anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 488 anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
Alexa Fluor® 647 anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
Pacific Blue™ anti-mouse CD117 (c-Kit) 2B8 FC
PerCP/Cyanine5.5 anti-mouse CD117 (c-kit) 2B8 FC
PerCP anti-mouse CD117 (c-kit) 2B8 FC
APC/Cyanine7 anti-mouse CD117 (c-kit) 2B8 FC
Brilliant Violet 421™ anti-mouse CD117 (c-Kit) 2B8 FC,SB
Purified anti-mouse CD117 (c-Kit) (Maxpar® Ready) 2B8 FC,CyTOF®
PE/Dazzle™ 594 anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 711™ anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 594 anti-mouse CD117 (c-Kit) 2B8 IHC-F,3D IHC
APC/Fire™ 750 anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 510™ anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 785™ anti-mouse CD117 (c-Kit) 2B8 FC
TotalSeq™-A0012 anti-mouse CD117 (c-kit) 2B8 PG
Brilliant Violet 605™ anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 700 anti-mouse CD117 (c-Kit) 2B8 FC
TotalSeq™-B0012 anti-mouse CD117 (c-Kit) 2B8 PG
TotalSeq™-C0012 anti-mouse CD117 (c-Kit) 2B8 PG
Spark NIR™ 685 anti-mouse CD117 (c-kit) 2B8 FC
Brilliant Violet 650™ anti-mouse CD117 (c-kit) 2B8 FC
Spark Red™ 718 anti-mouse CD117 (c-kit) (Flexi-Fluor™) 2B8 FC
Go To Top Version: 1    Revision Date: 06.30.2015

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account