Pacific Blue™ anti-mouse IL-10 Antibody

Pricing & Availability
Clone
JES5-16E3 (See other available formats)
Regulatory Status
RUO
Other Names
Interleukin-10, Cytokine synthesis inhibitory factor (CSIF), B cell derived T cell growth factor (B-TCGF)
Isotype
Rat IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
A_JES5-16E3_PB_092409
Th2 polarized C57BL/6 splenocytes stained with JES5-16E3 Pacific Blue™ and CD3 (17A2) PE
  • A_JES5-16E3_PB_092409
    Th2 polarized C57BL/6 splenocytes stained with JES5-16E3 Pacific Blue™ and CD3 (17A2) PE
  • B_JES5-16E3_PB_092409
    Th2 polarized C57BL/6 splenocytes stained with rat IgG2b isotype Pacific Blue™ and mouse CD3 antibody (17A2) PE
Compare all formats See Pacific Blue™ spectral data
Cat # Size Price Quantity Check Availability Save
505019 25 µg $147
Check Availability


Need larger quantities of this item?
Request Bulk Quote
505020 100 µg $347
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

IL-10 was originally described as Cytokine Synthesis Inhibitory Factor (CSIF) by virtue of its ability to inhibit cytokine production by Th1 clones. IL-10 shares over 80% sequence homology with the Epstein-Barr virus protein BCRFI. IL-10 inhibits IFN-γ, TNF-β, and IL-2 production by Th1 clones; inhibits macrophage-mediated IL-1, IL-6, and TNF-α synthesis; suppresses the delayed type hypersensitivity response; stimulates Th2 cell response (which results in elevated antibody production); and promotes mast cell proliferation in combination with IL-4.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
E. coli-expressed, recombinant mouse IL-10
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography, and conjugated with Pacific Blue™ under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICFC - Quality tested

Recommended Usage
Each lot of this antibody is quality control tested by intracellular immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 1.0 µg per 106 cells in 100 µl volume or 100 µl of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* Pacific Blue™ has a maximum emission of 455 nm when it is excited at 405 nm. Prior to using Pacific Blue™ conjugate for flow cytometric analysis, please verify your flow cytometer's capability of exciting and detecting the fluorochrome.
Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Violet Laser (405 nm)
Application Notes

ELISA or ELISPOT Detection1,9,11: The biotinylated JES5-16E3 antibody is useful as a detection antibody for a sandwich ELISA or ELISPOT assay, when used in conjunction with purified JES5-2A5 antibody (Cat. Nos. 504902 & 504904) as the capture antibody.
ELISA Capture: The purified JES5-16E3 antibody is useful as the capture antibody in a sandwich ELISA when used in conjunction with the biotinylated JES5-2A5 antibody (Cat. No. 505003) as the detection antibody and recombinant mouse IL-10 (Cat. No. 575809) as the standard.
Neutralization14: The Ultra-LEAF™ purified JES5-16E3 antibody can neutralize the bioactivity of natural or recombinant IL-10.
Flow Cytometry3: The fluorochrome-labeled JES5-16E3 antibody is useful for intracellular immunofluorescent staining and flow cytometric analysis to identify IL-10-producing cells within mixed cell populations.
Additional reported applications (for relevant formats) include: immunohistochemistry3.

Application References

(PubMed link indicates BioLegend citation)
  1. Simkin G, et al. 2000. J. Immunol. 164:2457.
  2. Kitagaki K, et al. 2002. Clin. Diagn. Lab Immunol. 9:1260.
  3. Khanna A, et al. 2000. J. Immunol. 164:1346.
  4. Sander B, et al. 1993. J. Immunol. Methods 166:201.
  5. Litton M, et al. 1994. J. Immunol. Methods 175:47.
  6. Andersson U, et al. 1999. Detection and qunatification of gene expression. New York:Springer-Verlag.
  7. Finkelman F, et al. 2003. Curr. Prot. Immunol. John Wiley & Sons New York. Unit 6.28.
  8. Wang W, et al. 2004. FASEB J. 18:1043.
  9. Brummel R and Lenert P. 2005. J. Immunol. 174:2429.
  10. Lawson BR, et al. 2007. J. Immunol. 178:5366.
  11. Xu G, et al. 2007. J. Immunol. 179:5358. PubMed
  12. Brummel R, et al. 2005. J. Immunol.174:2429. PubMed
  13. Kang YJ, et al. 2007. Stem Cells 25:1814. PubMed
  14. Seo N, et al. 2001. Immunology. 103:449. (Neut)
Product Citations
  1. Ramanan D, et al. 2020. Cell. 181(6):1276-1290. PubMed
RRID
AB_2125095 (BioLegend Cat. No. 505019)
AB_2125094 (BioLegend Cat. No. 505020)

Antigen Details

Structure
Acid-labile cytokine, dimer, 17-21 kD (Mammalian)
Cell Sources
Activated CD8+ T cells, Th0, Th2 subset of CD4+ T cells, Ly-1+ B cells, monocytes, macrophages, keratinocytes
Cell Targets
T cells, B cells, mast cells, macrophages
Receptors
IL-10R (CDw210)
Cell Type
Tregs
Biology Area
Immunology
Molecular Family
Cytokines/Chemokines
Antigen References

1. Fitzgerald K, et al. Eds. 2001. The Cytokine FactsBook. Academic Press San Diego.
2. de Waal-Malefy R, et al. 1992. Curr. Opin. Immunol. 4:314.
3. Howard M, et al. 1992. Immunol. Today 13:198.
4. Quesniaux V. 1992. Res. Immunol. 143:385.
5. Norton SK, et al. 2008. J. Immunol. 180:2848.

Regulation
Downregulated by IL-4, IL-10
Gene ID
16153 View all products for this Gene ID
UniProt
View information about IL-10 on UniProt.org

Other Formats

View All IL-10 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-mouse IL-10 JES5-16E3 ICFC
Biotin anti-mouse IL-10 JES5-16E3 ELISA Detection,ELISPOT Detection,ICFC
FITC anti-mouse IL-10 JES5-16E3 ICFC
PE anti-mouse IL-10 JES5-16E3 ICFC
Purified anti-mouse IL-10 JES5-16E3 ELISA Capture,CyTOF®,IHC
Alexa Fluor® 647 anti-mouse IL-10 JES5-16E3 ICFC
PE/Cyanine7 anti-mouse IL-10 JES5-16E3 ICFC
Alexa Fluor® 488 anti-mouse IL-10 JES5-16E3 ICFC
Brilliant Violet 421™ anti-mouse IL-10 JES5-16E3 ICFC
Pacific Blue™ anti-mouse IL-10 JES5-16E3 ICFC
PerCP/Cyanine5.5 anti-mouse IL-10 JES5-16E3 ICFC
Purified anti-mouse IL-10 (Maxpar® Ready) JES5-16E3 ELISA Capture,CyTOF®
Brilliant Violet 605™ anti-mouse IL-10 JES5-16E3 ICFC
PE/Dazzle™ 594 anti-mouse IL-10 JES5-16E3 ICFC
APC/Cyanine7 anti-mouse IL-10 JES5-16E3 ICFC
Ultra-LEAF™ Purified anti-mouse IL-10 JES5-16E3 ELISA Capture,CyTOF®,ELISPOT Capture,Neut,ICFC,IHC
Brilliant Violet 650™ anti-mouse IL-10 JES5-16E3 ICFC
Brilliant Violet 711™ anti-mouse IL-10 JES5-16E3 ICFC
Go To Top Version: 1    Revision Date: 11/30/2012

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account