Description

Erythropoietin (EPO) is the most important hormone regulating erythropoiesis. It is a glycoprotein also known as hematopoietin. EPO is mainly produced by kidney and liver in response to hypoxia to induce red blood cell production. Mouse EPO is a secreted protein of 166 amino acids with a predicted molecular mass of ~18.6 kD. However, it migrates on SDS-PAGE at ~33-48 kD due to heavy glycosylation. EPO is closely related to thrombopoietin (TPO) and highly conserved across species, with mouse EPO being 95% and 80% identical to rat and human, respectively.

EPO functions through binding to its receptor, EPO R, a homodimer, on erythoid precursors, and promotes their differentiation and maturation. As expected, serum levels of EPO are elevated in response to various conditions that result in tissue hypoxia (e.g., blood loss, high altitude, cardiac or pulmonary disease, and anemia). Increased EPO levels can also be due to increased production by cancer cells of the liver and kidney. Decreased levels of EPO are often seen with chronic renal failure and other chronic diseases, which causes anemia. Mouse endogenous EPO and recombinant EPO share the same amino acid sequence, with differences in the glycosylation profiles.

The LEGEND MAX™ Mouse EPO ELISA kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a rat monoclonal anti-mouse EPO antibody. The Detection Antibody is a biotinylated polyclonal goat anti-mouse EPO antibody. This kit is specifically designed for the accurate quantitation of mouse EPO from cell culture supernatant, serum, plasma (heparin), tissue homogenates and other biological fluids. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Anti-Mouse EPO Pre-coated 96 well Strip Microplate
  • Mouse EPO Detection Antibody
  • Mouse EPO Standard
  • Avidin-HRP
  • Assay Buffer A
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Reactivity
Mouse
Application

ELISA

Product Citations
  1. Sanchez A, et al. 2020. Sci Rep. 10:18469. PubMed
  2. Chatterjee S, Saxena R 2015. PLoS One. 10: 0132697. PubMed
Sensitivity
1.0 pg/mL
Standard Range
6.3 - 400 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µl to 1,000 µl
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Biology Area
Cell Biology, Signal Transduction
Molecular Family
Cytokines/Chemokines, Growth Factors
Gene ID
13856 View all products for this Gene ID
UniProt
View information about Erythropoietin on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Customers Also Purchased

Go To Top Version: 2    Revision Date: 12/14/2016

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere
Insert Note Here
Save Close Clear
Lab Timer
Tools
Login / Register
Remember me
Forgot your password? Reset password?
Create an Account